Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
An. bras. dermatol ; 87(3): 389-395, May-June 2012. graf
Article in English | LILACS | ID: lil-638527

ABSTRACT

BACKGROUND: Leprosy is a chronic infectious disease caused by Mycobacterium leprae. It is considered a major public health issue in developing countries. OBJECTIVES: To evaluate the clinical and epidemiological profile of leprosy patients between 2003 and 2008 in the state of Piauí, to analyze detection and prevalence rates in the general population and in the population of children under 15 years of age, and to evaluate the predominant clinical forms. METHODS: Data were obtained from the notifiable diseases database of the State Health Department, Piauí, Brazil. Medical records are retrieved from patients' charts using a specific questionnaire and the collected data is then entered into the database system. RESULTS: Of the 12,238 cases of leprosy reported in this period, 85% represented new cases. The mean overall annual detection rate was 54 cases/100,000 habitants. The rate for children under 15 years of age was 15.3 cases/100,000 habitants. Overall, 52.18% of the patients were male; 64.66% were between 20 and 59 years of age; and 53.53% had the paucibacillary form of leprosy. Nevertheless, in 88.82% of cases of the paucibacillary form of the disease, more than five lesions were present, while in 10.55% of cases of the multibacillary form of the disease, no lesions were present. Over 20% of patients had some degree of disability. CONCLUSION: These indicators point to a high circulation of bacilli in the community and highlight the extreme difficulty experienced by the primary healthcare network in organizing itself in order to ensure that patients with this complex disease receive an accurate and early diagnosis.


FUNDAMENTOS: A hanseníase é uma doença infecciosa crônica, causada pelo Mycobacterium leprae, sendo considerada um grande problema de saúde pública nos países em desenvolvimento. OBJETIVOS: Objetivou-se estudar o perfil clinicoepidemiológico dos pacientes com hanseníase no período de 2003 a 2008, no estado do Piauí, verificar suas taxas de detecção e de prevalência na população geral e em menores de 15 anos e avaliar as formas clínicas predominantes. MÉTODOS: Os dados foram obtidos a partir da base do Sistema de Informação de Agravos de Notificação da Secretaria de Saúde do estado do Piauí, sendo as informações procedentes dos prontuários médicos, organizadas em um questionário específico. RESULTADOS: Do total de 12.238 casos de hanseníase notificados no período em questão, 85% eram casos novos (taxa de detecção geral anual média de 54 casos/100.000 habitantes e em menores de 15 anos de 15,3/100.000 habitantes); 52,18 % eram homens, 64,66 % dos pacientes encontravam-se na faixa etária de 20 a 59 anos e 53,53 % apresentavam a forma paucibacilar. No entanto, 88,82% das formas paucibacilares apresentavam mais de cinco lesões e 10,55 % das formas multibacilares não tinham qualquer lesão. Mais de 20% dos pacientes tinham algum grau de incapacidade. CONCLUSÃO: Conclui-se que estes indicadores apontam para uma elevada circulação do bacilo na comunidade e a grande dificuldade que a rede básica apresenta de se organizar de forma a diagnosticar correta e precocemente os casos desta complexa doença.


Subject(s)
Adolescent , Adult , Child , Female , Humans , Middle Aged , Young Adult , Leprosy/epidemiology , Brazil/epidemiology , Disease Notification , Leprosy/diagnosis , Leprosy/drug therapy , Prevalence , Retrospective Studies
2.
Acta cir. bras ; 26(2): 140-143, abr. 2011. ilus
Article in English | LILACS | ID: lil-579642

ABSTRACT

PURPOSE: To introduce a model of equipment for inhalation anesthesia in rats that offers better control of both flow and losses of ether during induction, maintenance, and recuperation. METHODS: The equipment consists of an air compressor with two outlets, a closed glass induction chamber, a glass reservoir for the anesthetic agent, a pediatric inhalation mask, a three-way stopcock, a Y-connector, and urinary catheters. Three hundred Wistar rats (Rattus norvegicus albinus) were given inhalation anesthesia. The evaluated parameters were equipment operation, duration of each phase of anesthesia, corneal reflex, muscular tonus, respiration during induction and maintenance, and volume of anesthesia. RESULTS: The average time taken for induction was 7.3 minutes; the average anesthetic recuperation time was 6.4 minutes. The amount of anesthetic used varied according to the weight of the animal, with the average volume of ether used being 6.5ml/hour. The availability of oxygen (room air) decreased the recuperation time and averted both respiratory depression and insufficient depth of anesthesia. CONCLUSION: The proposed equipment is practical, inexpensive, and allows for satisfactory control of anesthetic parameters during the entire procedure, making inhalation anesthesia in rats safe and essentially complication free.


OBJETIVO: Apresentar modelo de equipamento para anestesia inalatória em ratos, com melhor controle do fluxo, das perdas de anestésico na indução, da manutenção e da recuperação anestésica. MÉTODOS: O equipamento é constituído por compressor de ar com saída dupla, câmara de vidro fechada para indução, reservatório de vidro para o agente anestésico, máscara de inalação pediátrica, torneira de três vias, conexão em "Y" e sondas uretrais. Trezentos ratos Wistar (Rattus norvegicus albinus) foram anestesiados por via inalatória. Os parâmetros avaliados foram: viabilidade do equipamento, tempo de cada fase, reflexo corneano, tônus muscular e movimentos respiratórios na indução e na manutenção anestésica, além do volume de anestésico. RESULTADOS: A média do tempo gasto na indução anestésica foi de 7,3 minutos. A média do tempo de recuperação anestésica foi de 6,4 minutos. A média do volume de éter utilizado foi de 6,5 ml/h. Não foram observadas neste experimento morte dos animais, aumento excessivo de secreção traqueobrônquica ou interrupção da operação por superficialização anestésica. CONCLUSÃO: O equipamento proposto é prático, possui baixo custo e permite o controle adequado dos parâmetros de controle da anestesia durante todo o procedimento, tornando a anestesia inalatória em ratos segura e praticamente isenta de complicações.


Subject(s)
Rats , Anesthesia , Rats/classification , Analgesia , Ether/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL